Personally, I think these two books are not bad. You can have a look. Their introduction and expenses. Power System Analysis, published by China Power Publishing House on February 2, 2010, the authors are Li Meilan and Lu Wenpeng.This book is a textbook recommended by the Department of Vocational Education and Adult Education of the Ministry of Education.
There are two main options for power system textbooks. One is He Yangzan's. This version is sorted in a mess, but some parts are more streamlined. One is from China Electric Power Publishing House. This version is very comfortable and detailed, and the content is relatively more complicated.
The fault analysis part of He Yangzan's textbook is very complete, and the complex fault analysis is well written. Other textbooks are not as good as it. However, there is no power system status estimation, static safety analysis and other contents, so it should be read by Zhu Junwei and Xia Daozhi's books later.
Usually there are only 2 sets. One set is the steady-state analysis of the power system of the power publishing house. The transient analysis, the third edition of Chen Yan's transient forgets what it is called.. One set is the first and second books of Huake He Yangzan's power system analysis..
Three-phase short circuit is also known as three-phase short circuit. It is a short circuit that the three phases A, B and C are directly connected without load.
Three-phase short circuit refers to the short circuit of two or more lines in three-phase four lines. The main types include three-phase short circuit, two-phase short circuit, single-phase short circuit and two-phase grounded short circuit.
Three-phase short circuit: three-phase A, B and C are connected together. Two-phase disconnection: A, B or B, C or C, A are two-phase disconnected, and only C, or A or B are charged. Two-phase electricity: only A, B or B, C or C and A have electricity. Three-phase electricity: A, B and C three-phase normally charged. Single-phase grounding: A or B or C one-phase grounding.
In a three-phase system, possible short circuits are: three-phase short circuit, two-phase short circuit, two-phase short circuit grounding and single-phase grounding short circuit. Three-phase short circuit is also known as symmetrical short circuit, and the system is still in a symmetrical state as during normal operation. Other types of short circuits are not symmetrical short circuits.
Of course, it is naturally better to have some understanding of other professional basic courses, such as Power System Equipment, Relay Protection, Automatic Control Principle, Advanced Language Programming (Current Computing Needs), etc. As long as you have studied circuit and electrical engineering, it is relatively easy to understand the analysis of the power system with a little effort.
The basics of power system analysis in the postgraduate entrance examination are related to undergraduate courses such as circuit principle, electrical engineering, electromagnetic field, engineering mathematics and automatic control theory.
In the analysis of the power system, it is relatively simple to calculate various parameters at the beginning, followed by current calculation, voltage adjustment, frequency adjustment, calculation of various short circuit situations, etc. These are relatively important. Just remember the formula and do some exercises. The most difficult part is related to the motor, which is generally not involved in the exam, except for the postgraduate entrance examination.
I think we should not only learn, but also learn the circuit well. Especially the content of resistive network analysis! The idea of "equivalent" should be applied skillfully. Learn the circuit well, and then learn the electrical division, so that it is much easier to learn the content of fault analysis and calculation.
Agritech products HS code classification-APP, download it now, new users will receive a novice gift pack.
Personally, I think these two books are not bad. You can have a look. Their introduction and expenses. Power System Analysis, published by China Power Publishing House on February 2, 2010, the authors are Li Meilan and Lu Wenpeng.This book is a textbook recommended by the Department of Vocational Education and Adult Education of the Ministry of Education.
There are two main options for power system textbooks. One is He Yangzan's. This version is sorted in a mess, but some parts are more streamlined. One is from China Electric Power Publishing House. This version is very comfortable and detailed, and the content is relatively more complicated.
The fault analysis part of He Yangzan's textbook is very complete, and the complex fault analysis is well written. Other textbooks are not as good as it. However, there is no power system status estimation, static safety analysis and other contents, so it should be read by Zhu Junwei and Xia Daozhi's books later.
Usually there are only 2 sets. One set is the steady-state analysis of the power system of the power publishing house. The transient analysis, the third edition of Chen Yan's transient forgets what it is called.. One set is the first and second books of Huake He Yangzan's power system analysis..
Three-phase short circuit is also known as three-phase short circuit. It is a short circuit that the three phases A, B and C are directly connected without load.
Three-phase short circuit refers to the short circuit of two or more lines in three-phase four lines. The main types include three-phase short circuit, two-phase short circuit, single-phase short circuit and two-phase grounded short circuit.
Three-phase short circuit: three-phase A, B and C are connected together. Two-phase disconnection: A, B or B, C or C, A are two-phase disconnected, and only C, or A or B are charged. Two-phase electricity: only A, B or B, C or C and A have electricity. Three-phase electricity: A, B and C three-phase normally charged. Single-phase grounding: A or B or C one-phase grounding.
In a three-phase system, possible short circuits are: three-phase short circuit, two-phase short circuit, two-phase short circuit grounding and single-phase grounding short circuit. Three-phase short circuit is also known as symmetrical short circuit, and the system is still in a symmetrical state as during normal operation. Other types of short circuits are not symmetrical short circuits.
Of course, it is naturally better to have some understanding of other professional basic courses, such as Power System Equipment, Relay Protection, Automatic Control Principle, Advanced Language Programming (Current Computing Needs), etc. As long as you have studied circuit and electrical engineering, it is relatively easy to understand the analysis of the power system with a little effort.
The basics of power system analysis in the postgraduate entrance examination are related to undergraduate courses such as circuit principle, electrical engineering, electromagnetic field, engineering mathematics and automatic control theory.
In the analysis of the power system, it is relatively simple to calculate various parameters at the beginning, followed by current calculation, voltage adjustment, frequency adjustment, calculation of various short circuit situations, etc. These are relatively important. Just remember the formula and do some exercises. The most difficult part is related to the motor, which is generally not involved in the exam, except for the postgraduate entrance examination.
I think we should not only learn, but also learn the circuit well. Especially the content of resistive network analysis! The idea of "equivalent" should be applied skillfully. Learn the circuit well, and then learn the electrical division, so that it is much easier to learn the content of fault analysis and calculation.
Supplier onboarding with data analytics
author: 2024-12-24 02:24How to find untapped export partners
author: 2024-12-24 01:56Predictive container utilization analytics
author: 2024-12-24 01:11HS code-driven market entry strategy
author: 2024-12-24 00:26HS code integration into supplier scorecards
author: 2024-12-23 23:59How to identify top importing countries
author: 2024-12-24 01:35How to identify monopolistic suppliers
author: 2024-12-24 00:47Commodity-specific import licensing data
author: 2024-12-24 00:40How to comply with export licensing
author: 2024-12-24 00:34154.34MB
Check275.57MB
Check824.95MB
Check276.92MB
Check751.95MB
Check186.42MB
Check675.75MB
Check762.79MB
Check736.69MB
Check711.69MB
Check154.93MB
Check428.81MB
Check356.48MB
Check663.43MB
Check766.29MB
Check542.33MB
Check864.63MB
Check725.29MB
Check832.54MB
Check114.88MB
Check518.16MB
Check925.95MB
Check437.24MB
Check486.59MB
Check625.11MB
Check678.12MB
Check346.18MB
Check189.76MB
Check821.46MB
Check894.45MB
Check532.78MB
Check694.91MB
Check925.91MB
Check196.15MB
Check865.62MB
Check528.59MB
CheckScan to install
Agritech products HS code classification to discover more
Netizen comments More
1158 Global trade lead generation tools
2024-12-24 02:30 recommend
2059 How to monitor competitor supply chains
2024-12-24 02:09 recommend
1489 HS code electrical machinery data
2024-12-24 00:22 recommend
1138 Industry-specific import regulation data
2024-12-24 00:17 recommend
1881 Marble and granite HS code references
2024-12-24 00:01 recommend