1. The fares of various systems of China's urban rail transit mainly include the one-ticket system of the route (one-ticket system for a single line, and you need to repurchase the ticket for transferring to other routes), mileage segmentation (setting the starting price and starting mileage to increase the price by advancing the mileage) and segmented segmentation (according to the station area There are three forms of ticket prices.
2. Single fare system (referring to the distance of the ride, only one ticket is issued on the whole line) Advantages: the ticketing speed is fast, the ticket inspection system is implemented, and there is no ticket inspection when entering and leaving the station, which can reduce the number of station operators. Disadvantages: It is not conducive to attracting short-distance passenger flow. Segmented fare system (referring to the distance or number of stations to sell tickets of different fares.
3. [Answer]: (1) The fare system of the urban rail transit system mainly includes the single fare system, the metering fare system, the section fare system and the regional fare system. ( 2) The single fare system refers to the implementation of a price regardless of the length of the operating mileage.
4. The first stage: manual ticket sales and inspection stage, single ticket price, paper tickets. For example, at the beginning of the opening of Line 1. ( 2) The second stage: manual ticket sales and inspection methods. For example, during the trial operation of Line 3, the ticket price adopts the multi-level metering ticket system and paper tickets.
1. The third-generation mobile communication system mainly has three systems: WCDMA, CDMA2000 and TD-SCDMA, among which EuropeZhou's WCDMA and U.S. CDMA2000 were developed on the basis of GSM system and CDMA system respectively, and TD-SCDMA is China's standard.
2. At present, there are four third-generation mobile communication standards: CDMA2000 in the United States, WCDMA in Europe, and TD-SCDMA and LAS-CDMA in China. From the perspective of technological development trend and business function, the three standards based on the CDMA system: TDSCDMA, WCDMA and CDMA2000 are regarded as the three mainstream application technology standards of 3G.
3. The three mainstream standards of G system are WCDMA (broadband CDMA), cdma2000 and TD-SCDMA (time-diplex synchronous synchronous CDMA).The comparison of the basic technical parameters of these three standards is shown in Table 1.
The system of the subway station environmental control system is divided into the following three types: Bus system: This system uses a unified bus to Connect all sensors and actuators for data transmission and control operations through the bus.
Open system: The open system is to apply mechanical or "piston effect" to exchange air between the inside of the subway and the outside world, and use the outside air to cool stations and tunnels. This system is mostly used in subway systems with an average monthly temperature of less than 25℃ and less transportation in the hottest local months.
According to the cooling capacity: large-scale airAdjustment system: Generally, the working area is very large, ranging from thousands of square meters to tens of thousands or even hundreds of thousands of square meters, and some can be up to hundreds of thousands of square meters. The system load capacity is usually hundreds to tens of thousands of cold tons.
The environmental control system of the subway has two main parts: the station ventilation and air conditioning system and the tunnel ventilation system. 1 Station ventilation and air conditioning system The ventilation and air conditioning system of the subway should be given priority to the ventilation system. When the ambient temperature reaches a certain condition, the station will adopt an air conditioning system.
The world's TV format is divided into PAL, NTSC and SECAM. The TV format adopted in China is PAL.
China adopts the PAL-D system, so the LCD TVs used in China should at least be compatible with the PAL-D system. LightningThe video signal of the video program is an analog signal composed of video analog data and video synchronization data, which is used to display images correctly at the receiving end. The details of the signal depend on the video standard or "system" applied.
According to different duplex modes, the LTE system is divided into FDD-LTE (Frequency Division Duplexing) and TDD-LTE (Time Division Duplexing). Both technologies The main difference lies in the physical layer of the empty port (such as frame structure, time design, synchronization, etc.).
LTE is actually a network system. What is well known isGSM, CDMA, GPRS, EDGE, etc. In fact, LTE is just a network system. TD-LTE is a wireless communication technology, and it is one of the 4G network wireless communication technologies that is faster than 3G networks.
LTE mainly includes two versions: TDDLTE and FDDLTE. The two systems are selectively applied according to the previous different 3G networks. For example, China Mobile adopts TDDLTE, because TDDLTE is very compatible with the 3G network independently developed by China Mobile.
1. The traction power supply system willThe AC medium-voltage voltage is converted into a voltage of DC 1,500 V or DC 750 V through voltage reduction and rectification, which provides traction power for electric trains. It includes a traction substation and a traction network. The traction network includes contact network and return network. The contact network has two suspension methods: overhead contact network and contact rail.
2. The traction network implements single-phase power supply, which is composed of feeder wire (referred to as feeder wire), contact network, (electric locomotive), track circuit and return flow line, etc. In order to supply electricity to electric locomotives effectively and reliably, phase-split insulators, segment insulators and other equipment are also installed on the traction network, and there are also sub-sections, opening and closing stations, etc. in the power supply system.
3. Power supply system Urban rail transit power supply system composition; substation, contact network, return network. The power supply system of the traction network mainly refers to the current system, voltage level and feeding mode.China's national standard subway DC traction power supply system stipulates two power supply systems: DC1500V and DC750V.
4. The "AC-DC-AC) variable frequency speed regulation method is usually adopted. Although the AC asynchronous motor is used on electric vehicles, its contact grid line power supply voltage is still DC. From the perspective of power supply, it can still be regarded as an expanded application of the DC power supply system.
Medical devices HS code mapping-APP, download it now, new users will receive a novice gift pack.
1. The fares of various systems of China's urban rail transit mainly include the one-ticket system of the route (one-ticket system for a single line, and you need to repurchase the ticket for transferring to other routes), mileage segmentation (setting the starting price and starting mileage to increase the price by advancing the mileage) and segmented segmentation (according to the station area There are three forms of ticket prices.
2. Single fare system (referring to the distance of the ride, only one ticket is issued on the whole line) Advantages: the ticketing speed is fast, the ticket inspection system is implemented, and there is no ticket inspection when entering and leaving the station, which can reduce the number of station operators. Disadvantages: It is not conducive to attracting short-distance passenger flow. Segmented fare system (referring to the distance or number of stations to sell tickets of different fares.
3. [Answer]: (1) The fare system of the urban rail transit system mainly includes the single fare system, the metering fare system, the section fare system and the regional fare system. ( 2) The single fare system refers to the implementation of a price regardless of the length of the operating mileage.
4. The first stage: manual ticket sales and inspection stage, single ticket price, paper tickets. For example, at the beginning of the opening of Line 1. ( 2) The second stage: manual ticket sales and inspection methods. For example, during the trial operation of Line 3, the ticket price adopts the multi-level metering ticket system and paper tickets.
1. The third-generation mobile communication system mainly has three systems: WCDMA, CDMA2000 and TD-SCDMA, among which EuropeZhou's WCDMA and U.S. CDMA2000 were developed on the basis of GSM system and CDMA system respectively, and TD-SCDMA is China's standard.
2. At present, there are four third-generation mobile communication standards: CDMA2000 in the United States, WCDMA in Europe, and TD-SCDMA and LAS-CDMA in China. From the perspective of technological development trend and business function, the three standards based on the CDMA system: TDSCDMA, WCDMA and CDMA2000 are regarded as the three mainstream application technology standards of 3G.
3. The three mainstream standards of G system are WCDMA (broadband CDMA), cdma2000 and TD-SCDMA (time-diplex synchronous synchronous CDMA).The comparison of the basic technical parameters of these three standards is shown in Table 1.
The system of the subway station environmental control system is divided into the following three types: Bus system: This system uses a unified bus to Connect all sensors and actuators for data transmission and control operations through the bus.
Open system: The open system is to apply mechanical or "piston effect" to exchange air between the inside of the subway and the outside world, and use the outside air to cool stations and tunnels. This system is mostly used in subway systems with an average monthly temperature of less than 25℃ and less transportation in the hottest local months.
According to the cooling capacity: large-scale airAdjustment system: Generally, the working area is very large, ranging from thousands of square meters to tens of thousands or even hundreds of thousands of square meters, and some can be up to hundreds of thousands of square meters. The system load capacity is usually hundreds to tens of thousands of cold tons.
The environmental control system of the subway has two main parts: the station ventilation and air conditioning system and the tunnel ventilation system. 1 Station ventilation and air conditioning system The ventilation and air conditioning system of the subway should be given priority to the ventilation system. When the ambient temperature reaches a certain condition, the station will adopt an air conditioning system.
The world's TV format is divided into PAL, NTSC and SECAM. The TV format adopted in China is PAL.
China adopts the PAL-D system, so the LCD TVs used in China should at least be compatible with the PAL-D system. LightningThe video signal of the video program is an analog signal composed of video analog data and video synchronization data, which is used to display images correctly at the receiving end. The details of the signal depend on the video standard or "system" applied.
According to different duplex modes, the LTE system is divided into FDD-LTE (Frequency Division Duplexing) and TDD-LTE (Time Division Duplexing). Both technologies The main difference lies in the physical layer of the empty port (such as frame structure, time design, synchronization, etc.).
LTE is actually a network system. What is well known isGSM, CDMA, GPRS, EDGE, etc. In fact, LTE is just a network system. TD-LTE is a wireless communication technology, and it is one of the 4G network wireless communication technologies that is faster than 3G networks.
LTE mainly includes two versions: TDDLTE and FDDLTE. The two systems are selectively applied according to the previous different 3G networks. For example, China Mobile adopts TDDLTE, because TDDLTE is very compatible with the 3G network independently developed by China Mobile.
1. The traction power supply system willThe AC medium-voltage voltage is converted into a voltage of DC 1,500 V or DC 750 V through voltage reduction and rectification, which provides traction power for electric trains. It includes a traction substation and a traction network. The traction network includes contact network and return network. The contact network has two suspension methods: overhead contact network and contact rail.
2. The traction network implements single-phase power supply, which is composed of feeder wire (referred to as feeder wire), contact network, (electric locomotive), track circuit and return flow line, etc. In order to supply electricity to electric locomotives effectively and reliably, phase-split insulators, segment insulators and other equipment are also installed on the traction network, and there are also sub-sections, opening and closing stations, etc. in the power supply system.
3. Power supply system Urban rail transit power supply system composition; substation, contact network, return network. The power supply system of the traction network mainly refers to the current system, voltage level and feeding mode.China's national standard subway DC traction power supply system stipulates two power supply systems: DC1500V and DC750V.
4. The "AC-DC-AC) variable frequency speed regulation method is usually adopted. Although the AC asynchronous motor is used on electric vehicles, its contact grid line power supply voltage is still DC. From the perspective of power supply, it can still be regarded as an expanded application of the DC power supply system.
Machinery exports HS code insights
author: 2024-12-24 01:30Real-time import duties calculator
author: 2024-12-24 01:03Japan customs transaction analysis
author: 2024-12-24 00:05Global trade analytics for decision-makers
author: 2024-12-23 23:59Medical diagnostics HS code classification
author: 2024-12-23 23:56HS code correlation with quality standards
author: 2024-12-24 02:28Trade data for GDP correlation analysis
author: 2024-12-24 01:08Industry-focused market entry reports
author: 2024-12-24 01:07How to minimize supply chain disruptions
author: 2024-12-24 00:44455.77MB
Check651.71MB
Check783.22MB
Check968.76MB
Check523.11MB
Check478.25MB
Check436.25MB
Check729.83MB
Check999.99MB
Check325.75MB
Check196.21MB
Check152.32MB
Check842.11MB
Check834.79MB
Check588.26MB
Check671.13MB
Check626.52MB
Check845.31MB
Check699.91MB
Check431.71MB
Check768.23MB
Check529.52MB
Check679.94MB
Check315.27MB
Check247.14MB
Check615.26MB
Check485.61MB
Check846.19MB
Check969.76MB
Check265.92MB
Check731.87MB
Check983.27MB
Check616.54MB
Check341.25MB
Check351.94MB
Check881.61MB
CheckScan to install
Medical devices HS code mapping to discover more
Netizen comments More
2348 Global trade metadata enrichment
2024-12-24 02:02 recommend
1627 HS code-driven risk management frameworks
2024-12-24 01:47 recommend
2502 HS code compliance training modules
2024-12-24 01:22 recommend
248 HS code-based quality control checks
2024-12-24 00:31 recommend
1274 Advanced materials HS code classification
2024-12-24 00:09 recommend